Repairing A Burst Coil On A Pressure Washer For A Pooling Company In Atherstone
What they needed
We were called out to a pooling company in Atherstone after their industrial hot pressure washer suffered a burst boiler coil. The machine is used regularly for cleaning equipment and vehicles, and the loss of hot water significantly impacted their operations.
Due to the urgency of the situation, we attended site and carried out a rapid coil replacement to minimise downtime.
Problem / Requirement
- Machine type: Industrial static hot pressure washer.
- Main issue: Burst boiler coil causing water leakage and loss of hot water function.
- Symptoms: Machine unable to generate heat and visible signs of coil failure.
- Operational impact: Cleaning operations disrupted due to loss of hot wash capability.
A burst coil renders the burner ineffective and can quickly escalate into further damage if not addressed immediately.
Our Solution
- Attended site promptly following the service call.
- Diagnosed burst boiler coil within the heating chamber.
- Removed the damaged coil assembly.
- Supplied and fitted a replacement boiler coil.
- Reassembled burner housing and heating system.
- Tested burner operation and checked for leaks.
Fully commissioned the system and verified safe hot water output
The result
- New boiler coil installed and fully operational.
- Hot water function restored.
- Machine back in service within 5 hours of receiving the call.
- Minimal downtime for the customer.
- Cleaning operations resumed the same day.
Rapid response and correct diagnosis ensured the customer avoided extended disruption.